Call: 888-611-7275

Call: 888-611-7275

Chemical Processing

SuperVault

Aboveground Fuel Tank

The SuperVault MH is the first tank to pass the SwRI 95-03 Multi-Hazard test, the toughest national test for aboveground fuel tanks. Most tanks are single-hazard rated which means they can withstand a hazard (fire, bullet, impact) one time, but then have
to be removed from service. The SuperVault MH has been tested for multiple exposure to fires and other hazards, plus an extended element exposure test. This means that if the SuperVault MH experiences a hazard, it may be recertified and kept in service rather than having to be replaced.

In addition to SwRI 95-03, the listing includes a 4-hour fire rating. It meets the stringent safety requirements of Uniform Fire Code Appendix Standard A-II-F-1 (UFC 79-7), SwRI Test Procedure 93-01, NFPA 30/30A, and UL 2085 Protected Tank and Interstitial Communication Test.

Features
Dolor Sit Amet

  • Known for excellent service
  • 20-Year transferable warranty
  • Light weight, easy to install and relocate
  • Optional precast slabs customized for SuperVault
  • Fleet of crane trucks for delivery & placement on slab
  • True “Field Testable” secondary containment
  • True 110% secondary containment
  • 4-Hour fire rating
  • Bullet resistance
  • High impact resistance
  • Seismic restraints part of every tank
  • External diking not required by UFC
  • Custom equipment packages factory installed -
          ready for use
  • Only tank listed reusable after a hazard (subject to fire
           official inspection)
SuperVault MH

MH Series Cylindrical Tanks: Available from 250 gallons to 20,000 gallons, the cylindrical line of the MH Series offers two advantages to the fleet fueling operation: larger capacities and less wasted fuel in the bottom of the tank. For example, let’s say a suction tube is cut 6” from the bottom of a fuel tank to avoid settling debris or water common with fuel storage. In a 12,000 gallon rectangular tank, the end user would have approximately 840 gallons of unusable fuel at 6”. At 6” in a 12,000 gallon cylindrical tank, the volume left is only 240 gallons. This means the owner of a 12,000 gallon SuperVault has 600 additional gallons, 71% more in the bottom 6” than larger rectangular ASTs.

MH Series Rectangular Tanks: Rectangular SuperVaults are available from 250 gallons to 2,000 gallons. The advantages of rectangular designs are smaller footprints, less visual impact and simplicity in operating tank-top pumps and accessories.

Cylindrial SV Resources

File Preview ⬎

MH-CYL-1

Summary of cyl. SuperVaults

MHD1-250

250 gal. cyl. SuperVault

MH500

500 gal. cyl. SuperVault

MH750

750 gal. cyl. SuperVault

MH1K

1000 gal. cyl. SuperVault

MH1500

1500 gal. cyl. SuperVault

MH2K

2000 gal. cyl. SuperVault

MH3K

3000 gal. cyl. SuperVault

MH4K

4000 gal. cyl. SuperVault

MH5K

5000 gal. cyl. SuperVault

MH6K

6000 gal. cyl. SuperVault

MH8K

8000 gal. cyl. SuperVault

MH10K

10000 gal. cyl. SuperVault

MH12K

12000 gal. cyl. SuperVault

MH15K

15000 gal. cyl. SuperVault

MH20K

20000 gal. cyl. SuperVault

8KS2

8000S2 gal. cyl. SV - split 6000/2000 gal

WalkerCo10k

10000 gal cyl. SV - accessorized w/ submersible pumps

EL10-04

(2)/1000 gal. cyl. SV w/ custom fabricated platform

D510k

10000 gal. cyl. SV w/ external remote spill containment

12KS2

12000 gal cyl. SV w/ (4) ground level pump stations

Flyer

SuperVault Flyer

Rectangular SV Resources

File Preview ⬎

MHR-REC

Summary of rec. SuperVaults

MHR250

250 gal. rec. SuperVault

MHR25-2

250 gal. rec. SV - split 125/125 gallons 

MHR-500

500 gal. rec. SuperVault

MHR05-2

500 gal. rec. SV - split 250/250 gallons

MHR1000

1000 gal. rec. SuperVault

MHR10-2

1000 gal. rec. SV - split gallon options

MHR1500

1500 gal. rec. SuperVault

MHR15-2

1500 gal. rec. SV - split gallon options

MHR2000

2000 gal. rec. SuperVault

MHR20-2

2000 gal. rec. SV - split gallon options

Installation Ideas SV Resources

File Preview ⬎

BOLLARD

Typical UFC/IFC Impact Bollard requirements

REC-SLABS

Foundation Pad  Structural - Rec. SV

REC-LEGS

Support Legs - Size & Embedment (Seizmic Zone 4)

CYL-SLAB

Foundation Pad Structural - Cyl. SV

CYL-LEGS

Support Legs - Size & Embedment (Seizmic Zone 4)

GEN1

Generator Acc. PKG - Suction Supply, Bobtail Delivery

GEN2

Generator Acc. PKG - Suction Supply, Transport Delivery

GEN3

Generator Acc. PKG - Pump Supply, Bobtail Delivery

GEN4

Generator Acc. PKG - Suction Supply, Transport Delivery

D702TM

Top Mounted Diesel Dispensing PKG - Bobteil Delivery

U702TM

Top Mounted Unleaded Dispensing PKG - Bobtail Delivery

GF713-902

Ground-level Fill & Dispensing - 18gpm

GF313-902

Ground Level Fill & Dispensing - 30gpm

WASTE

Waste Oil PKG - Rec. Tanks

500-GEN-CONTAIN

500 gal. w/ leak tight enclosure protecting exterior piping

500-TYP GEN R

500 gal rec. SV - typical Generator fitting top view

8K-TYP GEN

MH-D4 8000 gal. cyl. SV - typical Generator fitting top view

1K-D-TM-REEL

1000 gal rec. SV w/ external hose reel

1K-D-TM

1000 gal. rec. SV w/ top mount diesel pump top view

6K-D-DUAL

6000 gal. cyl. SV - split for off & on road diesel fueling

10K-D-DUAL